IR Furnace Features

  pdf version

Base Equipment and Options (C)

KEYDESCRIPTION
CACTClosed Atmosphere Cooling Tunnel. The CACT is a 76.2 cm (30 inch) long, high efficiency heat exchanger that reduces the temperature of the product.  Inside the CACT, process gas flows through air rakes arranged two above the belt to cool the product to a safe temperature.  To expedite heat removal, fans outside the chamber force ambient room air over the heat sink finned surfaces on the outside of the tunnel. Multiple tunnels may be joined end-to-end to obtain required cooling.  Standard on many furnace configurations, option available on most furnaces.  IR Furnace Optional Equipment
CAWCClosed Atmosphere Water Cooled Tunnel. The CAWC is a 76.2 cm (30 inch) long, high efficiency heat exchanger that reduces the temperature of the product, but without externally mounted heat sink cooling fans. Instead, water flowing through chambers above and below the tunnel removes heat from the tunnel walls without adding to the heat load in the clean room. Includes OI integrated outlet water temperature sensors and alarms.  Requires water supply and drain.  Multiple tunnels may be joined to obtain required cooling.  Upgrade from CACT.   Standard on many furnace configurations, option available on most furnaces.  IR Furnace Stardard Equipment  IR Furnace Optional Equipment
CB-1Circuit Breaker.  Three phase circuit breaker.  Required for UL approval.  Option available on most furnaces.  IR Furnace Optional Equipment
CDA-LCDA Lockout.  Manual lockout for CDA supply line, 1724 kPa, 250 psi.  Option available on most furnaces.  IR Furnace Optional Equipment
CDA-SCDA Auto Shutdown.  Automatically shuts off CDA supply after actual furnace Power OFF to reduce compressor load and gas consumption.  Includes timed delay to assure clearing of all process gas and emissions from furnace chamber.  Note:  furnace control delays actual Power OFF until furnace cools to 100 C.  Option available on most furnaces. IR Furnace Optional Equipment
CFLCabinet Fans, Lower.  Provides a high air volume impeller fan, located below the belt, to remove excess heat from the product and cabinet interior. Used with CMB30 and CMB45 Cross-flow Fan Cooling Modules. Standard on all furnace configurations with CMB30 or CMB45 modules.  IR Furnace Stardard Equipment  IR Furnace Optional Equipment
CMTurbulent Air Cooling Module.  Provides a 76.2 cm (30 inch) long, fan-driven cooling module consisting of two rows of 3 m3/min (106 cfm) fans that force ambient air over all surfaces of the product. This module can be used to bring massive or high‑speed product to handling temperature quickly. Controlled atmosphere processes should be reviewed to assure that the product is below its oxidation temperature before reaching the air cooling. The fan speed is controlled via the control console. Standard on some furnace configurations, option available on most furnaces.   IR Furnace Stardard Equipment  IR Furnace Optional Equipment
CMB30Forced Air Cooling Module. Supplies fan-driven ambient air for rapid convection cooling of product on the belt. This 76.2 cm (30 inch) long, forced air cooling module uses two top-mounted cross-flow 13.3 m3/min (471 cfm) fans to force ambient air into a plenum assembly located above the belt, resulting in a downward laminar flow over the entire surface area of the belt directly under the cooling module. Controlled atmosphere processes should be reviewed to assure that the product is below its oxidation temperature before reaching the air cooling. Fan speed is controlled via the control console.  Multiple modules may be joined to obtain required cooling. Standard on some  furnace configurations, option available on most furnaces.  IR Furnace Stardard Equipment  IR Furnace Optional Equipment
CMB45Forced Air Cooling Module. Supplies fan-driven ambient air for rapid convection cooling of product on the belt. This 1.143 m (45 inch) long, forced air cooling module shall use three top-mounted cross-flow 13.3 m3/min (471 cfm) fans to force ambient air into a plenum assembly located above the belt, resulting in a downward laminar flow over the entire surface area of the belt directly under the cooling module. Controlled atmosphere processes should be reviewed to assure that the product is below its oxidation temperature before reaching the air cooling. Fan speed is controlled via the control console.  Multiple modules may be joined to obtain required cooling. Standard on some  furnace configurations, option available on most furnaces.  IR Furnace Stardard Equipment IR Furnace Optional Equipment
CWWCCold Wall Water Cooling Module.  High efficiency, 50.8 cm (20 inch) long, water-cooled module that improves heat transfer from cooling tunnel, more rapidly reducing the temperature of the product.  Includes OI integrated inlet and outlet water temperature sensors and alarms.  Requires water supply and drain.  Multiple modules may be joined to obtain required cooling.  Upgrade from CACT. Standard on some furnace configurations, option available on most furnaces.  IR Furnace Optional Equipment
CXE15Entrance Conveyor Extension.  Extends load station at the entrance of the furnace or dryer.  Adds 0.381 m (15 inches) to length of furnace. 
Option available on most furnaces.  IR Furnace Optional Equipment
CXX15Exit Conveyor Extension.  Extends unload station at the exit of the furnace or dryer.  Adds 0.381 m (15 inches) to length of furnace.  Option available on most furnaces.  IR Furnace Optional Equipment

Used Furnaces
New Furnaces
eMail for Quote

 

Corporate Offices:

30025 Alicia Pkwy
Laguna Niguel, CA 92677 USA

 

P
:  1.949.218.4996
Furnace Pros

 

Office Hours:

Monday - Friday
7:00 AM - 4 PM PST

FurnacePros Furnace Pros for RTC Infrared IR Production Belt Furnace Help